PILZ PSSu E S 2DOR 10

Rs. 0.00

Technical Data
Electrical Data
Permitted loads
  • Resistive
  • Inductive
Relay Outputs
Number of relay outputs 2
Utilisation cat. AC/DC1 standard EN 60947-4-1
Utilisation cat. AC15/DC13 standard EN 60947-5-1
Safety contacts: AC at UL 240 VAC G. P.
Safety contacts: pilot duty 3.0 A
Contact relay fuse protection to EN 60947-5-1
Relay contact material AgCuNi
Potential isolation RlCont - Uint1 4900 V (safe separation)
Potential isolation RlCont to U2 4900 V (safe separation)
Potential isolation RlCont1 to CRail 3050 V (basic insulation)
Potential isolation RlCont1 to RlCont2 4900 V (safe separation)
Environmental Data
Climatic suitability to ...
  • EN 60068-2-30
  • EN 60068-2-2
  • EN 60068-2-1
  • EN 60068-2-78
  • EN 60068-2-14
Ambient temperature standard EN 60068-2-14
Ambient temperature 0 - 60 °C
Ambient temp. with UL 60 °C
Storage temperature standard EN 60068-2-1/-2
Climatic suitability standard
  • EN 60068-2-30
  • EN 60068-2-78
Humidity rating 93 % r. h. at 40 °C
Condensation permitted? Not permitted
Perm. operating height ASL 2000 m
EMC to standard ...
  • EN 61131-2
  • EN 61000-4-4
  • EN 61000-4-5
  • EN 61000-4-6
  • EN 61000-4-2
  • EN 61000-4-3
Vibration to standard ... EN 60068-2-6
Acc. shock to standard 1 15g
Clearance & creepage dist. to EN 60664-1
Overvoltage category II
Pollution degree clearance & creep. 2
Protection type standard EN 60529
Mechanical Data
Housing material lower section PC
Housing material front plate PC
Housing material code PA
Terminal style Plug-in
Height dimension 76 mm
Width dimension 25.2 mm
Depth dimension 60.2 mm
Net weight 62 g
Gross weight 71 g
Name of coding element I
Colour of coding element Dark grey

Out of stock

May 12 - May 16

Hurry Up! Only 1000 Left in Stock!

SUA00002903