PILZ PSS u2 ES 4AI U

SUA00003077

Technical Data
Analog Inputs
Number of Analog Inputs4
Type of Analog InputsVoltage
Analog Input Signal Type 1Differential Input
Analog Input Signal Range 1-12.8 V - +12.8 V
Analog Input Signal Type 2Differential Input
Analog Input Signal Range 2-6.4 V - +6.4 V
Analog Input Signal Type 3Differential Input
Analog Input Signal Range 3-3.2 V - +3.2 V
Type of Input FilterRC Filter, 1st Order
Value of Least Significant Bit U-Me
  • 97.65625 µV (-3.2 V - +3.2 V)
  • 195.3125 µV (-6.4 V - +6.4 V)
  • 390.625 µV (-12.8 V - +12.8 V)
Resolution of Analog Inputs16 Bit
Monotony without Error CodesYes
Conversion Method Analog InputSuccessive Approximation
Max. Processing Time Analog InputInput Filter + 0.1 ms
Potential Isolation Analog InputYes
Environmental Data
Climatic Suitability to
  • EN 60068-2-30
  • EN 60068-2-2
  • EN 60068-2-1
  • EN 60068-2-78
  • EN 60068-2-14
Ambient Temperature StandardEN 60068-2-14
Ambient Temperature-25 - 60 °C
Storage Temperature StandardEN 60068-2-1/-2
Climatic Suitability StandardEN 60068-2-78
Humidity Rating93 % r.h. at 40 °C
Condensation Permitted?No
Perm. Operating Height ASL2000 m
EMC to StandardEN 61131-2 (Zone B)
Vibration to StandardEN 60068-2-6
Acc. Shock to Standard 1150 m/s²
Clearance & Creepage Dist. toEN 61131-2
Overvoltage CategoryII
Pollution Degree Clear. & Creep.2
Protection Type StandardEN 60529
Potential Separation
Potential Isolation 1 BetweenAnalog Input and Module Supply
Type of Potential Isolation 1Functional Insulation
Potential Isolation 2 BetweenAnalog Input and Periphery Supply
Type of Potential Isolation 2Functional Insulation
Potential Isolation 3 BetweenPeriphery and Module Supply
Type of Potential Isolation 3Functional Insulation
Mechanical Data
Housing MaterialPC
Terminal StylePlug-in
Height Dimension110.8 mm
Width Dimension12.5 mm
Depth Dimension72.5 mm
Net Weight36 g
Gross Weight52 g