PILZ PSSu H PLC1 FS SN SD M12-R

Rs. 0.00

Technical Data
Electrical Data
Purpose of U1Module supply
Supply voltage (V)24 V
Type of supply voltage U1DC
Power consumption DC16 W
Purpose of U2Periphery supply
Supply voltage 2 (V)24 V
Type of supply voltage U2DC
Tolerance of U2-30 % / +25 %
Pot. isolation UINT1 to U2
Purpose of UINT1int. system voltage
Type of UINT1DC
Tolerance of UINT1-2 % / +3 %
Max. curr. contin. oper. UINT12 A
Bridge U-interrupt UINT1 stan.
UINT1 short circuit proofYes
Programming
IEC 61131 programmingYes
Multi programmingYes
Non-volatile variablesYes
CPU
Time deviation+/- 10s/day
RAM128 MB
User memory total4 MB
NV user memory FS section382 kB
Removable Storage Media
Plug-in memorySD card
SafetyNET p Interface
Connector type Safetynet i/fM12
Safetynet transmission rate100 MBit/s
Setting SafetyNet trans. rateAutomatic
SafetyNET p cycle time2 ... 60 000 ms
PROFINET Interface
Settable trans. rate PROFINET100 MBit/s
Trans. rate setting PROFINETAutomatic
PROFINET certificationPNO
PROFINET manufacturer ID092Fh
Connector type PROFINET i/fM12
PROFINET typeSlave
Cycle time PROFINET IO DEVICE4 ... 512 ms
Modbus/TCP
MODBUS cycle time2 ... 2 000 000 ms
EtherNet/IP Adapter
Cycle time EtherNet/IP4 ... 655 000 ms
EDS file EtherNet/IP00B5000C00010100.eds
Device type EtherNet/IPAdapter
Supported EtherNet/IP RPI4 ... 655 000 ms
Raw UDP
RAW UDP cycle time2 ... 2 000 000 ms
Environmental Data
App. site standard1 railwayEN 50125-3
App. site to standard1 railwayTrack area (1m - 3m)
App. site standard2 railwayEN 61373
App. site to standard2 railwayCategory 1, Class A + B
Climatic suitability to
  • EN 50125-1
  • EN 60068-2-2
  • EN 60068-2-1
  • EN 50155
  • EN 60068-2-14
  • EN 50125-3
Ambient temperature standardEN 50155
Ambient temperature-40 - 70 °C
Standard 2 for ambient temp.EN 50125-1
Ambient temp. to standard 2-40 ... +70 °C
Standard 3 for ambient temp.EN 50125-3
Ambient temp. to standard 3-40 ... +70 °C
Climatic suitability standardEN 60068-2-78
Humidity rating
Condensation permitted?No
Perm. operating height ASL2000 m
EMC to standard
  • EN 50121-4
  • EN 50121-3-2
  • EN 61000-6-2
  • EN 61000-6-4
Broad band noise toEN 50125-3
Standard1 b/band noise, railEN 61373
Freq. broadband noise, rail5 ... 150 Hz
Accel. broadband noise, rail
Acceleration broadband noise
Clearance & creepage dist. toEN 50124-1
Overvoltage categoryOV2
Pollution degree clear. & creep.PD2
Protection type standardEN 60529
Mechanical Data
Housing material lower sectionPC
Connection terminalScrew terminal, Spring-loaded terminal
Terminal stylePlug-in
Flex. cond. c/s AWG info24 - 12 AWG
Height dimension125.6 mm
Width dimension130 mm
Depth dimension83.7 mm
Net weight370 g
Gross weight420 g

Out of stock

Apr 29 - May 03

Hurry Up! Only 1000 Left in Stock!

SUA00002834